Fire Alarm

  • MICTRON 9900 SYSTEM
  • MICTRON 900 MULTIPLEX SYSTEM
  • SERIES C DETECTORS & DEVICES
  • MAIN SYSTEM
  • SERIES AX DEVICES
  • OPTIONAL SUB-SYSTEM
  • TECHNICAL SPECIFICATION

Mictron 9900 Main System

The Mictron 9900 analog addressable fire alarm system is suitable for simple to complex installations, it can interface up to 16 loops in a single cabinet.

Each loop can interface up to 126 series AX detectors & devices.

Features:
  • From 1 to 16 loops
  • Hard or soft devices addressing
  • LCD based fire zone display
  • Built-in 10A power supply/charger
  • SERIES AX DEVICES

AX-9SL Optical Smoke Detector

  • Dual LED alarm indicators for 360º viewing angle.
  • Advance sensor logic circuit with analog convector for smoke level discrimination algorithms
  • Unique sensing chamber for smoke detection, with wire mesh for protection against dirt, dust and flying insects
  • Built-in remote LED (Light Emitting Diode) driver

AX-9HL ROR & FT Heat Detector

  • Rate of Rise (ROR) & Fixed Temperature heat detector.
  • Dual LED alarm indicators for 360º viewing angle.
  • Built-in output circuit to drive external LED indicator.
  • Electronic thermistor sensor is use for long term accuracy & reliability.

AX-9SCi Loop Line Short Circuit Isolator

  • Isolator base fully compatible with standard AX smoke/heat detector base
  • Built-in LED indicators for normal & isolated conditions
  • Automatically reset when the loop line returned to normal

AX-9BG Break Glass

  • Red LED alarm indicator when glass is shattered
  • Unique Alarm/Reset test tool for easy maintenance
  • Optional protective clear plastic cover for double action alarm activation

AXM-1ZV-A 1 Zone & 1 Output I/O Unit

  • Designed for 1 sounder/control output and 1 flow switch zone input.
  • Small & compact design for easy installation
  • Housed in a robust casing for added protection, suitable for indoor & outdoor installation.

AXM-1ZV-B 4 Status Input I/O Unit

  • Designed for 4 unsupervised inputs or 1 supervised input & 3 unsupervised inputs.
  • Compact design for directly integrated into the panel to be interfaced.
  • Suitable for monitoring of pump, CO2 panel, valve input as well as 1 zone input.

Optional Sub-System

M9900-LED-R1 The LED based Repeater is also part of the main system, the LED will indicate the alarm, fault & disabled status of the zone

M9900-Mimic-R2 The multi-colour mimic panel consists of all floor plans and section of the building on perspex sheet, the LEDs on mimic floor plans will indicate the location of each fire zone.

M9900-LCD-R3 The LCD based Repeater is used to indicate device & zone information on the LCD display.

M9900-SFAP-R4 The sub-panel (Sub Fire Alarm Panel) can be part of main system, but located away from the main panel, it has the addressable devices connected to it and all the zone information are repeated at the main panel

M9900-PC-R5 The PC based user interface running on MS windows is used to display all device & zone information & floor plans on the screen.

M9900-Link-R6 The RS232 linking is provided for communicating with other building services system.

Brand Mictron
Model 9900
Part Number AXP-M9900
Input Power 240VAC 50Hz
Power Consumption 24V DC 150mA (exclude loop power)
Operating Temperature 0ºC - 45ºC
Humidity Max 95% (non-condensation)
Panel Construction Mild steel
Panel Thickness 1.5mm thickness
Finishing Epoxy powder coated paint
Colour Light gray or red
Dimension 720mm (W) x 430mm (H) x 150mm (D)
Weight 18.6kg (exclude battery)
Testing Standard MS1745 Part2 : 2004 EN 54 Part2 : 2004
Test Report 2014EEB0449, SIRIM
  • MAIN SYSTEM
  • RPPU
  • OPTIONAL SUB-SYSTEM
  • TECHNICAL SPECIFICATION

Mictron 900 Multiplex System

Mictron 900 is a Multiplex Fire Alarm System, also known as "semi addressable" system. A standard Mictron 900 system consists of 2 buses. Each bus can interface up to 16 RPPU

The Central controller gather all information from the remote RPPU and process into visual and audio signals. The visual signals consist of LED display indicating locations of fire zones and indications. A graphical mimic will also display all the fire zones. The audio signal will alert security personnel of the occurrence of a fire situation.

The operator keyboard allows security personnel to perform the necessary steps as to disable or reset a fire zone.

Features :
  • From 20 to 1000 zones
  • With full zone & status LED display
  • Compatible with all conventional devices
  • Design for easy user operation
  • Built-in 10A power supply/charger

RPPU is a data gathering panel whereby all external devices are connected, the RPPU is compatible with series C conventional detectors & devices, as well as other conventional devices make by 3rd party.

There are 2 types of RPPU :

RPPU-32 Completed with 32 inputs, 3 bells/siren & 9 tripping outputs.

RPPU-12 Completed with 12 inputs, 2 bells/siren & 2 tripping outputs

Optional Sub-System

M900-LED-R1 The LED based Repeater is part of the main system, the LED will indicate the alarm, fault & disabled status of the zone, as well as non-urgent point such as pump status.

M900-Mimic-R2 The multi-colour mimic panel consists of all floor plans and section of the building on perspex sheet, the LEDs on mimic floor plans will indicate the location of each fire zone.

M900-REP-R3 The Repeater can be just a LCD/keyboard panel, or combination of LCD/keyboard with zone display panels.

M900-SFAP-R4 The sub-panel (Sub Fire Alarm Panel) can be part of main system, but located away from the main panel, it has the RPPU connected to it and all the zone information are repeated at the main panel

M900-PC-R5 The PC based user interface running on MS windows is used to display all zones information & floor plans on screen.

M900-Link-R6 The RS232 linking is provided for communicating with other building services system.

Brand Mictron
Model 900
Part Number AXP-M900
Microprocessor Freescale MC9S12 & Rabbitcore 2000
Memory 512Kb Flash & 64Kb RAM
Ports 2 RS232 & 2 Multidrop RS485 & 2 parallel
Fire Brigade Link Volt - free contact
Input Power 240VAC 50Hz
Power Consumption 24V DC 150mA (exclude RPPU power)
Operating Temperature 0ºC - 45ºC
Humidity Max 95% (non-condensation)
Panel Construction Mild steel
Panel Thickness 1.6mm thickness
Finishing Epoxy powder coated paint
Colour Red or Signal Red
Dimension 600 (W) x 530 (H) x 180 (D)
Weight 30kg (inclusive of 2 x 12V battery)
Testing Standard MS1745 Part2 : 2004 EN 54 Part2 : 2004
Test Report 2014EEB0212, SIRIM
  • CONVENTIONAL DEVICES
  • TECHNICAL SPECIFICATION
  • CONVENTIONAL DEVICES

C-9SL Conventional Optical Smoke Detector

  • Dual LED alarm indicators for 360º viewing angle, LED flashing in standby mode.
  • Advance sensor logic circuit with analog convector for smoke level discrimination algorithms
  • Unique sensing chamber for smoke detection, with wire mesh for protection against dirt, dust and flying insects
 

AX-9HL ROR & FT Heat Detector

  • Unique ALARM/RESET test tool for easy maintenance.
  • Mounting back box with wire entry hole suitable for flush or surface mounting
  • Optional protective clear plastic cover for double action alarm activation.

C-9BL Conventional Bell

  • Unique swinging mechanism to prevent jamming
  • High quality steel dome generates clear & loud sound.
  • Low power DC motor with gear driven hitting rings.
SMOKE DETECTOR HEAT DETECTOR
Brand Mictron Mictron
Model Series C Series C
Type Photoelectric ROR & Fixed temperature
Part Number C-9SL C-9HL
Rated Voltage 24V DC 24V DC
Operating Voltage 12-35V DC 12-35V DC
Standby 100uA 55uA
Current 70mA 50mA
Alarm Current (max) 80mA 80mA
Permissible Current (max) - 57ºC
Alarm Fixed Temperature - Thermistor
Temperature Source Infrared LED -
Light 80m² at 6m height 30m² at 6m height
Source IP42 IP42
Coverage Area -10 to +50ºC -10 to +50ºC
IP Rating 95% RH(Non condensing) 95% RH(Non condensing)
Temperature Range 15mA with diode gate 15mA with diode gate
Operating Humidity 130g with base 160g with base
Remote Output ABS ABS
Weight 100mm x 46mm with base 100mm x 46mm with base
Color White White
Dimension EN 54-7, DIFT EN 54-5, DIFT
Approved Standard Certificate Number 0845-CPD-232.1618 0845-CPD-232.1617
Test 2014EEB0449 Humidity
Test 2014EEB0449 Humidity



  BREAK GLASS ALARM BELL
Brand Mictron Mictron
Model Series C Series C
Type Non resettable DC Motor Bell
Part Number C-9BG C-9BL
Operating Voltage 17-30V DC 20-28V DC
Alarm Current (max) 20mA 30mA
Alarm Resistance Sound Output 470 ohms -
Temperature Range -20 to +70ºC -20 to +60ºC
Operating Humidity 95% RH (Non condensing) 90% RH (Non condensing)
Weight 153g (with base) 764gm
Material ABS High Quality Steel
Dimension 88mm x 88mm x 59mm 150mm (Dia) x 56mm
Colour Signal Red Signal Red
Approved Standard EN54-11, MS1745-11 EN554-3, MS1745-3
Test Report 2008EL0517, SIRIM 2008EL0094, SIRIM